AC Servo Systems
SV2 series
Three-phase or single phase AC200 to 240V for 400WSV2-040L2
Specifications
Model |
SV2-040L2 |
|||
General specifications |
Capacity |
400 W |
||
Input power supply |
电压/频率 |
Main circuit |
3-phase (or single phase) 200 to 240 VAC +10 to -15%, 50/60 Hz |
|
Control circuit |
Single-phase 200 to 240 VAC +10 to -15%, 50/60 Hz |
|||
Allowable frequency fluctuation |
Main circuit/control circuit |
No more than ±5% |
||
Overvoltage category |
III |
|||
Control mode |
Three-phase full-wave rectification, IGBT, PWM control, sine-wave current driving method |
|||
回馈 |
22-bit serial encoder (absolute) communication, |
|||
Operating environment |
Operating atmosphere |
Enclosure rating |
IP20 |
|
Pollution degree |
Pollution degree: 2 (in an IP54 or higher control panel) |
|||
Operating ambient temperature |
-5 to +60°C23 to 140°F(no freezing; reduced ratings at +55°C131°For more) |
|||
Storage ambient temperature |
-20 to +85°C-4 to +185°F(no freezing) |
|||
Operating/storage ambient temperature |
95% RH or less (no condensation) |
|||
高度 |
2000 m6561.7'or less above sea level (usable at reduced ratings at 1000 m3280.8'or more) |
|||
Vibration resistance |
4.9 m/s216.1'/s2(符合JIS C60068-2-6) |
|||
Impact resistance |
19.6米/秒264.3'/s2(符合JIS C60068-2-27标准) |
|||
Other |
No static electricity noise, strong electric fields, magnetic fields, or radiation present |
|||
Min. insulation resistance |
500 VDC, 1 MΩ or more with insulation resistance tester |
|||
Applied standard |
UL/CSA standards |
UL61800-5-1, CSA22.2 No.274 |
||
CE标记 |
Low-voltage directive |
EN61800-5-1, EN50178 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Structure |
Type |
Attached to base mount |
||
Safety function |
STO function (STO/EN61800-5-2) |
|||
Safety function |
Safety parameters |
SIL3/EN61508, SIL CL 3/EN62061, |
||
Response time |
8 ms (max.) |
|||
Input |
STO1, STO2: Base block signal for power module |
|||
Output |
EDM: Built-in safety circuit status monitoring (fixed output) |
|||
Applied standard |
EN61800-5-2, EN ISO13849-1: 2008, EN61508, EN62061, EN60204-1, EN61326-3-1 |
|||
Protection function |
过电流,过压,欠压,过载,再生异常等。 |
|||
Insulation withstand voltage |
1500 VAC or more (between primary side and ground) |
|||
Weight |
Approx. 1.0 kg |
|||
Power supply/current capacity and power loss |
Main circuit power supply |
Three-phase 200 V/Single phase 200 V |
||
最大限度。适用的电机容量 |
400 W |
|||
Power supply capacity for 1 amplifier |
Three-phase 200 V: 1 kVA, Single phase 200 V: 1.2 kVA |
|||
Output current |
Continuous |
2.8 Arms |
||
最大限度。 |
9.3 Arms |
|||
Main circuit power loss |
24 W |
|||
Regenerative resistor power loss |
— |
|||
控制电路功率损耗 |
17 W |
|||
Total power loss |
41 W |
|||
Rated input current |
Main circuit |
Three-phase 200 V: 2.5 Arms, Single phase 200 V: 5.0 Arms |
||
Control circuit |
0.2 Arms |
|||
Rush current |
Main circuit |
34 A |
||
Control circuit |
||||
Performance specifications |
Performance |
Speed control range |
1:5000 (load torque ≤ rated torque conditions) |
|
Speed fluctuation rate |
At load fluctuation |
±0.01% or less with load fluctuations of 0 to 100% (at rated rotation speed) |
||
At main circuit voltage change |
0% with ±10% of rated voltage (at rated rotation speed) |
|||
At ambient temperature change |
±0.1% or less with ambient temperatures of 0 to +50°C32 to 122°F(at rated rotation speed) |
|||
Torque control accuracy (reproducibility) |
±1% |
|||
速度响应频率 |
2.6 kHz |
|||
Dynamic brake |
Operated at main circuit power supply OFF, servo alarm, limit switch detection (LSP/LSN), forced stop detection (FSTOP) |
|||
Regenerative resistor |
Built-in regenerative resistor: 50 W to 400 W ... not installed |
|||
Display Function |
Panel function |
7-segment LED |
||
Status display LED |
CHARGE: For notification of main circuit power supply input (orange) |
|||
Auxiliary function |
增益控制,报警历史,z阶段搜索等 |
|||
I/O specifications |
序列输入信号 |
Number of inputs |
7 (3 high-speed input, 4 general input) |
|
最大限度。input voltage |
28.8 VDC |
|||
Rated input voltage |
24 VDC |
|||
Min. ON voltage |
19 VDC |
|||
Min. OFF current/voltage |
高速输入:0.6 mA,一般输入:0.3 |
|||
Common point mode |
7 points/1 common point (1 terminal) (bidirectional) |
|||
Input time constant |
250μs,500μs,1 ms,2.5ms,5 ms,10 ms |
|||
Input current |
High-speed input: 4.5 mA, general input: 3.7 mA |
|||
Input impedance |
Approx. 4.7 kΩ |
|||
Assignable input signals |
Full signal assignment, logic-settable forced stop (FSTOP), |
|||
序列输出信号 |
Number of outputs |
4 |
||
Output mode |
Transistor NPN output |
|||
Rated load |
30 VDC / 50 mA |
|||
Leakage current when OFF |
0.1 mA |
|||
Residual voltage when ON |
1.5 VDC or less |
|||
Common point mode |
Independent common |
|||
Assignable output signals |
Individual signal assignment excluding ALARM signal, logic-settable alarm (ALARM), |
|||
Analog Feedback Input signal monitor |
最大限度。input voltage |
±12 V |
||
Accuracy |
±1% of F.S. |
|||
解决 |
±10 bits |
|||
Input impedance |
30 kΩ |
|||
Encoder division pulse output signal |
Output mode |
阶段(+ /−),B阶段(B + / B−)、Z (Z + / Z−)阶段:Differential line-driver output |
||
Line driver |
SN75ALS174 (T.I.) or equivalent |
|||
Output frequency |
1.6 Mbps(具有2阶段,4倍乘法,6.4 MHz或等效)*3 |
|||
Analog monitor output |
No. of channels |
2 ch |
||
Output range |
±10 V (linearity valid range ±8 V) |
|||
解决 |
16 bits |
|||
Conversion precision |
±20 mV (typ.) |
|||
最大限度。allowable load current |
±10 mA |
|||
Conversion speed |
1.2 ms (typ.) |
|||
Communication specifications |
MECHATROLINK-III communication |
Communication protocol |
MECHATROLINK-III |
|
Station address |
03H to EFH (Max. number of connectable slaves: 62) |
|||
Transmission speed |
100 Mbps |
|||
Transmission frequency |
125 μs, 250 μs, 500 μs, 750 μs, 1 to 4 ms (in multiples of 0.5 ms) |
|||
通信周期 |
苏pport for values starting at transmission frequency × 1 |
|||
Number of transmitted bytes |
32 bytes/station, 48 bytes/station (selectable with slide switch) |
|||
Transmission media/cable |
Category 5e-compliant, STP cross cable |
|||
Operating specifications |
Position control / speed control / torque control |
|||
Command input |
MECHATROLINK-III command |
|||
最大限度。transmission distance |
50 m164.0'*4 |
|||
USB communication |
Connected device |
PC |
||
Communication standard |
USB 2.0-compliant |
|||
Function |
Status display, parameter setting, tuning, etc. |
|||
*1When using a DC power supply input, set “*AC/DC power supply” to “DC”. |
||||