流动传感器软管型号Ø48-63FD-H63F

Specifications

模型

FD-H63F

类型

Hose model

Supported pipe diameter

Ø48-63ø1.89“-2.48”

188bet在线支持的管材

Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1

Supported fluids

所有液体(水,油,化学品等)*1

188bet在线支持的液体温度

0–100°C32–212°F(no freezing on pipe surface)*2

Maximum rated flow

500 L/min
132.1 gal/min

Zero cut flow rate

5.0 L / min
1.3 Gal / min(variable, initial value)

Detection principle

Delta TOF

Function for automatic correction for speed of sound in liquid

Display

QVGA 2.0型号:彩色LCD,状态指示灯

Display update cycle

约。10 times/second

Display resolution

Instantaneous flow

0.01 / 0.1 / 1(l / min)(默认值:1)

Integrated flow

0.01/0.1/1 (L) (default value: 1; up to 8 digits)

Response time

0.5 S / 1.0 S / 2.5 S / 5.0 S / 10.0 S / 30.0 S / 60.0 S / 120.0 S / 200.0 S.

测量精度

重复性

0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4

Hysteresis

多变的

流量单位

L/min m3/ h g / min

Pulse output increments (L)

0.02–999.99

管道温度测量精度

网络支持188bet在线

IO-Link.*5

Heat calculation function

单元

MJ/h kW kBTU/h*6

Display resolution

瞬时值(mj / h):0.01 / 0.1 / 1(默认值0.1);集成值(MJ):0.01 / 0.1 / 1(默认值0.1)*6

Pulse output increments (MJ)

0.02–999.99*6

Data accumulation

Accumulation period

约。1年

数据阅读

USB2.0

电源I / O连接器

M12 8-pin connector (male)

I/O (switchable)

输出(CH1 / 2/3/4)

Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output
NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less

Analog output (Ch1/2)

4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less

外部输入(CH2 / 3)

集成复位输入/流量零输入/零点调整输入/银行输入
Short circuit current: 1.5 mA or less; input time: 20 ms or more

Power supply

电源电压

20–30 VDC, ripple (P-P) 10% included, Class 2/LPS

目前的消费

240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7

保护电路

Protection against reverse power connection, power supply surges, output short circuits, and output surges

环境抵抗力

Enclosure rating

IP65/67 (IEC 60529)*8

Ambient temperature

Sensor head: −20 to +60°C–4 to +140°F(没有冻结); Display unit: −20 to +50°C-4至+ 122°F(没有冻结)*2

相对湿度

35–85% RH (no condensation)

抗振

10-500 Hz;功率谱密度:0.816g2/赫兹;x,y和z方向

Shock resistance

100 m/s2(approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes

Material

Display unit

Body: PPS/PET/POM; Display window: PAR

Sensor head

身体:PPS / PET / PAR / SUS304;电缆:PVC
Sensor element: special rubber; Mounting bracket: PPS/PBT/POM/SUS304/SUSXM7

Weight

approx. 1360 g47.97盎司

*1For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.
*2当显示单元直接安装在传感器头上时,根据环境温度和流体温度存在脱墨。
*3这是核心检查设施验证的保证值。根据客户管道,流体类型,流体温度和其他因素的类型,可能发生测量误差。
*4In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.
*5Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.lambarine.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*6Can be used when two temperature sensors (sold separately) are connected.
*7640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).
*8使用USB连接时,IP65 / 67合规性受损。

Other Models