Digital Pressure Sensor with 2-Color Display
AP-C40 series
Contact Us:1-888-539-3623Inquiry form
Amplifier Unit, Main Unit, NPNAP-V41W
Specifications
Model |
AP-V41W |
|||
Type |
Amplifier Unit, NPN |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44 |
|||
Display |
4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm0.18"), AI indicator (green) Display cycle: 10 times/s |
|||
Operation indicator |
Red LED × 2 (corresponding to control output 1 and control output 2) |
|||
Display resolution |
AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 720 mW (60 mA) max., 24 V: 960 mW (40 mA) max. |
||
Display temperature characteristic |
±1%的F.S.或更少 |
|||
Hysteresis |
Standard mode: 0.5 % of F.S., high-resolution mode: 0.1 % of F.S., hysteresis variable mode (F-2): variable |
|||
Response time (Chattering prevention function) |
1/2.5/5/100/500 ms (selectable; 1 ms is used when high-speed mode is selected) |
|||
I/O |
Analog output |
1 to 5 V, output impedance: 1 kΩ or less (switchable with zero shift input) |
||
Zero-shift input |
Input time: 2 ms or more (switchable with analog output) |
|||
Control output |
Maximum NPN open-collector output: 100 mA (40 V or less), residual voltage: 1 V or less, 2 outputs (N.O./N.C. switchable)*1 |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Power consumption |
Eco mode |
12 V: 480 mW (40 mA) max., 24 V: 720 mW (30 mA) max. |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C32 to 122 °F(No freezing) |
||
相对humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Accessories |
Mounting bracket, head connection connector |
|||
Weight |
Approx. 80 g (with 2 m cable) |
|||
*120 mA or less when extended |
||||