安全Light Curtain

SL-C series

该模型已停止。

Recommended Replaceable Products:主机,手动式,48光轴 - GL-R48H

Main Unit, Robust Type, 48 Optical AxesSL-C48HM

Specifications

Model

SL-C48HM

Effective aperture angle

Max. ±2.5° (when operating distance is at least 3 m9.8')

Response time

15毫安*1

Light source

Infrared LED (850 nm)

Detection capability

Ø25mm(未使用消隐功能时)

Operation mode

Turned on when light is being applied to all optical axes (excluding when the blanking function is used)

No. of beam axes

48

Detection zone

940 mm37.01"

Protection area

985 mm38.78"

DetectingdistanceTransmitter lens: Norbornene plasticReceiver lens cover: Polyarylate

0.25 to 9 m

Beam axis interval

20 mm0.79"

Lens diameter

OSSD output

Output type

2 outputs each for PNP and NPN, Can be switched using the connection connector cable

Max. load current

300 mA*2

OFF-state voltage

2.5 V(电缆长度为7米23.0')

Leakage current

100 µA maximum*3

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring resistance

2.5 Ω maximum*4

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15 Class A

安全

IEC61496-1, EN61496-1, UL61496-1 (type 4 ESPE),IEC61496-2, EN61496-2, UL61496-2 (type 4 AOPD),UL508

Current consumption

Transmitter

87 mA

Receiver

90 mA

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Enclosure rating

IP65 (IEC60529)*5

Ambient light

Incandescent lamp: 5,000 lux or less, Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C14 to 131 °F(No freezing)

Storage temperature

-10 to +60 °C14 to 140 °F(No freezing)

Operating relative humidity

35 to 85 % RH (No condensation)

Storage relative humidity

35 to 95 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2(Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Weight

Transmitter

Approx 3.2 kg

Receiver

Approx 3.3 kg

*1OFF→返回时间为125毫秒。
*2Note the derating illustrated in the graph to the right when using PNP output.
*3This includes situations in which the SL-C Series is off and in which the power supply line is disconnected.
*4The wiring resistance between the OSSD output and the connected equipment (excluding the wiring resistance of the optional dedicated cable) must be 2.5 Ω or less to ensure that the SL-C Series operate correctly. If using the NPN output
*5The SL-CHM Series attains a protection rating of IP65 because the main unit's sensor is enclosed in an aluminum case.