Safety Controller
SC series
Expansion UnitSC-T01
Specifications
Model |
SC-T01 |
|||
再保险sponse time |
60 ms (safety output ON to OFF, IEC/EN60204-1 stop category 0), 120 ms (safety output OFF to ON) (including when the 0 second has been selected for the SC-T01 off display timer) |
|||
再保险sponse time when using OFF-delay timer |
Off delay timer: 0.2, 0.4, 0.6, 0.8, 1, 2, 5, 10, 15 seconds (selectable; safety output ON to OFF, IEC/EN60204-1 stop category 1), timer error: -0%, +10% |
|||
Safety output (S-OUTPUT) |
Output |
Two PNP outputs |
||
Output voltage |
Depends on the power supply voltage (26.4 VDC maximum) |
|||
Max. load current |
500 mA |
|||
再保险sidual voltage (when ON) |
2.5 V maximum (with a load current of 500 mA) |
|||
Leakage current |
1 mA maximum |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
|||
Load wiring length |
30 m maximum |
|||
Safety input (S-INPUT, enable input) |
Input type |
Contact output device connection or PNP output device connection |
||
Short-circuit current |
Approx 5mA |
|||
ON/OFF voltage |
Voltage when product turned on: 19 V or more, voltage when product turned off: 5 V or less (when a contact device connection is made to the 2-channel side input: voltage when product turned on: 5 V or less, voltage when product turned off: 19 V or more) |
|||
Wiring length |
30 m maximum |
|||
Safety related input |
Input type |
No-voltage contact input (EDM input, master reset input, group reset input) |
||
Short-circuit current |
EDM input: Approx. 10 mA, reset input: Approx. 5 mA (EDM input, master reset input, group reset input) |
|||
Wiring length |
30 m maximum (EDM input, master reset input, group reset input) |
|||
Non-safety output |
Output |
PNP/NPN totem pole output (Notification output 1 to 4, AUX output, interlock-reset-ready output, lockout output) |
||
Output voltage |
Depends on the power supply voltage (26.4 VDC maximum) (Notification output 1 to 4, AUX output, interlock-reset-ready output, lockout output) |
|||
Max. load current |
50mA (Notification output 1 to 4, AUX output, interlock-reset-ready output, lockout output) |
|||
再保险sidual voltage |
2.5 V maximum (with a load current of 50 mA) (Notification output 1 to 4, AUX output, interlock-reset-ready output, lockout output) |
|||
Leakage current |
1 mA maximum (Notification output 1 to 4, AUX output, interlock-reset-ready output, lockout output) |
|||
Load wiring length |
10 m maximum (Notification output 1 to 4, AUX output, interlock-reset-ready output, lockout output) |
|||
Non-safety input |
Input type |
No-voltage contact input or PNP or NPN open-collector input (external off input, teach mode input, teach preparation completion input) |
||
Short-circuit current |
Approx 5mA (external off input, teach mode input, teach preparation completion input) |
|||
ON/OFF voltage |
Voltage when product turned on: 5 V or less or 19 V or more, voltage when product turned off: open or 9 V to 15 V (external off input, teach mode input, teach preparation completion input) |
|||
Wiring length |
10 m maximum (external off input, teach mode input, teach preparation completion input) |
|||
Protection circuit |
电源反向极性保护ion, overcurrent protection for each output, short-circuit protection , surge protection |
|||
Approved standards |
EMC |
EMS |
IEC/EN/UL 61496-1, IEC62061 |
|
EMI |
EN55011 ClassA, FCC Part15 ClassA, ICES-003 Issue4 ClassA |
|||
Safety |
ISO13849-1:2015 (Cat.4, PL e), IEC/EN61496-1,EN50178,UL1998,UL508 |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less, Class 2, output hold time: 20 ms or more |
||
Current consumption |
1.2 A per unit |
|||
Environmental resistance |
Enclosure rating |
IP20 (IEC60529) |
||
Pollution degree |
2 (IEC60664/EN50178) |
|||
Overvoltage category |
2 (IEC60664, EN50178) |
|||
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between the internal circuit and the external case |
|||
Operating ambient temperature |
-10 to +55 °C14 to 131 °F(No freezing) |
|||
Storage temperature |
-20 to +65 °C-4 to 149 °F(No freezing) |
|||
Operating relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage relative humidity |
35 to 85 % RH |
|||
Altitude |
2,000 m or less |
|||
Withstand voltage |
1,500 VAC, 50/60 Hz for 1 minute between the internal circuit and the external case |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2(Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Polycarbonate (UL94-V2) |
||
Weight |
170 g or less |
|||