Digital Fiber Optic Sensors
FS-N series
Fiber Amplifier, Zero-line Expansion UnitFS-N10
Specifications
Model |
FS-N10 |
|||
Type |
0-line |
|||
Main unit/expansion unit |
Expansion |
|||
Control output |
N/A*1 |
|||
Light source LED |
Red, 4-element LED |
|||
APC |
ON/OFF switchable (Factory setting: OFF) |
|||
Response time |
50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
|||
Number of interference prevention units |
0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA |
|||
Unit expansion |
Up to 16 units can be connected total (two output type is treated as two units) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current Consumption |
Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*2 |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less |
||
Ambient temperature |
-20 to +55 °C-4 to +131 °F(No freezing)*3 |
|||
相对湿度 |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Both main unit and expansion unit housing material: Polycarbonate |
|||
Weight |
Approx. 20 g |
|||
*1Counted as 1 output when connecting with the network unit NU Series. |
||||