Separate Amplifier Model, Amplifier Units Cable Type Expansion unit NPNLR-XN12N

Specifications

Model

LR-XN12N

Type

NPN Output

电缆/Connector

电缆

Main Unit/Expansion Unit

Expansion Unit

No. of Control Outputs

2

No. of External Inputs

1

Response Time

500 µs*1/1 ms/3 ms/10 ms/200 ms可选

IO-Link

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I / O

Control Output

Open collector, 30 VDC or lower, N.O./N.C.
When used as a solitary unit: 100 mA or lower for 1 output; 100 mA or lower in total for 2 outputs; When expanding with multiple units: 50 mA or lower for 1 output
剩余电压NPN:1.4 V或更低(输出电流:10 mA或较低)/2 V或较低(输出电流:10至100 mA)

External Input

External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable
短路电流-NPN:1 mA或较低
Input time: 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF only when External Set is selected)

Unit Expansion

Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series.

Protection Circuit

Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection

Number of Interference Prevention Devices

OFF/4个单位/8个单位可选*2

Power supply

电压

16 to 30 VDC*3(including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 1060 mW (44 mA or lower at 24 V, 61 mA or lower at 16 V), ECO ON/ALL: 895 mW (37 mA or lower at 24 V, 50 mA or lower at 16 V) (excluding Load Current)

Environmental resistance

Ambient temperature

−20 to +55°C-4°F至131°F(no freezing)*4

相对湿度

35至85%RH(无凝结)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/赫兹;x,y和z方向

Shock resistance

500 m/s2(50G); 3 times each for X, Y, and Z axes

Case Material

Main Unit and Cover: Polycarbonate

配件

Instruction manual

Weight

大约70 g

*1If 500 µs is selected, the following limitations apply.
·只能执行2分校准。
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
· The interference prevention function is not supported
*2Selecting four or eight interference prevention units causes the response time to change as follows: 4 Units selected: 6 ms/18 ms/60 ms/1.2 s selectable; 8 Units selected: 12 ms/36 ms/120 ms/2.4 s selectable.
*3When expanding the system with 4 or more expansion units, use a power voltage of 20 V or higher.
*4Expansion by 1 or 2 units: −20 to +55°C-4°F至131°F; Expansion by 3 to 10 units: -20 to +50°C-4°F to 122°F, Expansion by 11 to 16 units: -20 to +45°C-4°F to 113°F