SpecsDigital Laser SensorLV series

Model

LV-H47

Image

Type

Area definite reflective

FDA (CDRH) Part 1040.10

Class II

Light source

Visible red semiconductor laser

Wavelength

660 nm

Detecting distance

FINE

55 to 85 mm2.17" to 3.35"

TURBO

SUPER

Environmental resistance

Ambient temperature

-10 to +55 °C14 to 131 °F(No freezing)

相对湿度

35 to 85 % RH (No condensation)

Material

Case

Glass reinforced plastic

Lens cover

Glass*1

Weight

Approx. 45 g

*1The LV-H47 and the LV-H42 receivers are polyarylate.

Back to top

Model

LV-H67

Image

Type

High power

FDA (CDRH) Part 1040.10

Class II

Light source

Visible red semiconductor laser

Wavelength

660 nm

Detecting distance

FINE

20 m65.6'

TURBO

30 m98.4'

SUPER

30 m*198.4'

Environmental resistance

Ambient temperature

-10 to +55 °C14 to 131 °F(No freezing)

Material

Case

Glass reinforced plastic

Lens cover

Transparent plastic*2

Reflective mirror

ABS塑料,Acrylic

Weight

Approx. 45 g

*1The detecting distance is 50 m164.0'when OP-42198 is used.
*2Norbornene plastic or acrylic

Back to top

Model

LV-H64

LV-H65

Image

Type

Long distance

Wide

FDA (CDRH) Part 1040.10

Class II

Light source

Visible red semiconductor laser

Wavelength

660 nm

Detecting distance

FINE

100 to 500 mm3.94" to 19.69"(100 to 700 mm3.94" to 27.56")*1

100 mm3.94"(150 mm5.91")*1

TURBO

200 to 850 mm (300 to 1000 mm)
7.87" to 33.46" (11.81" to 39.37")*1

10 to 150 mm0.39" to 5.91"(10 to 250 mm0.39" to 9.84")*1

SUPER

400 to 1200 mm (600 to 1500 mm)
15.75" to 47.24" (23.62" to 59.06")*1

100 to 200 mm3.94" to 7.87"(150 to 350 mm5.91" to 13.78")*1

Environmental resistance

Ambient temperature

-10 to +55 °C14 to 131 °F(No freezing)

Material

Case

Reinforced glass/plastic

Lens cover

Norbornene plastic

Reflective mirror

Polycarbonate, acrylic

Weight

Approx. 45 g

*1括号表示wh的探测距离en OP-51428 is used.

Back to top

Model

LV-H35F*1

LV-H62F*1

Image

Type

Straight-beam coaxial

Retro-reflective

FDA (CDRH) Part 1040.10

Class II

Light source

Visible red semiconductor laser

Wavelength

660 nm

Detecting distance

FINE

100 mm3.94"

1.5 m4.9'

TURBO

200 mm7.87"

3.5 m3.5'

SUPER

450 mm17.72"

5 m16.4'

Environmental resistance

Ambient temperature

-10 to +55 °C14 to 131 °F(No freezing)

相对湿度

35 to 85 % RH (No condensation)

Material

Case

Fluoroplastic (PFA)

O-ring

Fluororubber

Lens cover

Glass

Weight

Approx. 80 g

Approx. 100 g

*1The cable minimum bend radius is 25 mm0.98".

Back to top

Model

LV-21A

LV-21AP

LV-22A

LV-22AP

Image

Type

NPN output

PNP output

NPN output

PNP output

Main unit/expansion unit

Main unit

Expansion unit (1 line)

Control output

NPN open-collector x 2 channels, 40 VDC max., max. 100 mA, residual voltage (1.0 V max.)

PNP open-collector x 2 channels, 30 VDC max., max. 100 mA, residual voltage (1.0 V max.)

NPN open-collector x 2 channels, 40 VDC max., max. 100 mA, residual voltage (1.0 V max.)

PNP open-collector x 2 channels, 30 VDC max., max. 100 mA, residual voltage (1.0 V max.)

Response speed

FINE : 80 µs , TURBO : 500 µs , SUPER , TURBO : 4 ms

Number of interference
preventive units

FINE : None , TURBO : 2 units , SUPER : 4 units

Protection circuit

Reversed polarity protection, over-current protection, surge absorber

Unit expansion

Up to 7 additional expansion units can be installed (8 units including the main unit),

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 10 % or less

12 to 24 VDC, Ripple (P-P) 10 % or less (For the LV-20A/22A/22AP, the power supply voltage is supplied from the main unit.)

Power consumption

1.5 W max. (125 mA max. for 12 V, 62.5 mA max. for 24 V)

Environmental resistance

Ambient temperature

-10 to +55 °C14 to 131 °F(No freezing)*1

相对湿度

35 to 85 % RH (No condensation)

Material

Main unit

Polycarbonate

Case

Weight

Approx. 120 g

Approx. 75 g

Approx. 120 g

*1When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.
When 2 to 5 units: -10 to +50 °C14 to 122 °F
When 6 to 7 units: -10 to +45 °C14 to 113 °F
When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.

Back to top