Amplifier Separate Type Photoelectric Sensor

PS-N series

CatalogsView Catalog

Amplifier Unit, Zero-line Expansion UnitPS-N10

Specifications

Model

PS-N10

Type

Zero line

Output

-

Main unit/Expansion unit

Expansion unit

I / O

Control outputs

None*1

External input

None

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Timer function

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max.

Control output

Number of interference prevention units

4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled)

Response time

500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

External input

Input time 2 ms (ON)/20 ms (OFF) or more*2

Case size

H 32.6 mm1.28"× W 9.8 mm0.39"× L 78.7 mm3.1"

单位扩展

Up to 17 main units can be connected

Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Rating

Power voltage

24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS

Power consumption

Normal: 810 mW or less (at 30V. 28 mA max. at 24 V, 34 mA max. at 12 V)
Eco on mode: 700 mW or less (at 30V. 24 mA max. at 24 V, 27 mA max. at 12 V) Eco Full mode: 490 mW or less (at 30V. 17 mA max. at 24 V, 20 mA max. at 12 V)

Environmental resistance

Ambient temperature

-20 to +55 °C-4 to 131 °F(No freezing)*3

相对湿度

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Case

Main unit and cover material: Polycarbonate

Cable

PVC

Weight

Approx. 20 g

*1Counted as one output when added to a NU Series communication unit.
*2Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected.
*3If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
One or two more units connected: -20 to +55 °C-4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C-4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C-4 to 113 °F.