High Accuracy Contact Type Digital Display Displacement Sensor
AT-V series
Recommended Replaceable Products:High-Accuracy Digital Contact Sensor - GT2 series
Contact Us:1-888-539-3623Inquiry form
Amplifier UnitAT-V501HP
Specifications
Model |
AT-V501HP |
|||
Sensor head interchangeability |
Yes |
|||
Display |
Display |
Measurement |
7-segment 2-color LED (green and red) |
|
Sub display |
7-segment 1-color LED (red) |
|||
Common |
Minimum display |
0.1 µm0.004 Mil |
||
Display range |
-99999 to 99999 |
|||
Display speed |
20 times/second |
|||
Over-range alarm |
±FFFFF is displayed. |
|||
Sampling rate |
2000 times/second |
|||
Control input |
Timing input |
15 to 30 V is applied. |
||
Reset input |
||||
Auto-zero input |
||||
External setting input |
||||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
HIGH/GO/LOW |
PNP open-collector: 50 mA max. (30 V max),Residual voltage: 0.5 V max (N.C.) |
|||
Response time |
1.5 ms (at maximum speed) |
|||
Off-delay time |
60 ms (ON/OFF selectable) |
|||
Alarm output |
PNP open-collector: 50 mA max. (30 V max),Residual voltage: 0.5 V max (N.C.) |
|||
Analog output voltage |
Output range |
±0.5 V |
||
Impedance |
100 Ω |
|||
Response time |
4.5 ms (at maximum speed) |
|||
RS-232C interface |
Measurement data outputs and control inputs |
|||
温度查racteristics |
0.01% of F.S./°C*1 |
|||
Major functions |
Auto-zero function, Offset function (4 sets), Measurement modes (7 types), Judgment value memory function (4 sets),Statistical processing display function, Average function, Internal trigger function, Calibration function,Decimal point/display digit change function, Analog output scaling function, and ECO mode |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
150 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C32 to 122 °F |
||
相对湿度 |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 200 g |
|||
*1“F.S.” indicates the measurement range. Indicating the typical value at a temperature of 0 to +50°C32 to 122°F. |
||||