
General Purpose Digital Contact Sensor
GT series
放大器单元,面板安装Type, NPNGT-76A
Specifications
Model |
GT-76A |
|||
Type |
Amplifier unit |
|||
Mounting method |
Panel mount |
|||
Output |
NPN output |
|||
Main unit/expansion unit |
Expansion unit*1 |
|||
Power consumption |
Normal |
At 12 V: 1,140 mW (95 mA) or less, At 24 V: 1,200 mW (50 mA) or less |
||
Power saving (Eco) |
At 12 V: 600 mW (50 mA) or less, At 24 V: 840 mW (35 mA) or less |
|||
Display power |
Measured value display |
6-digit 7-segment LED (red) |
||
Other displays |
2-color 13-level bar LED display (red, green), indicators (red, green) |
|||
Display range |
-99.999 to 999.999 |
|||
Display resolution |
1 µm0.000039" |
|||
Sampling rate |
2,000 times/second |
|||
Control input |
Timing/preset/bank input |
Timing input: Non-voltage input (relay contact, solid state), input time: 2 ms or more |
||
Response time |
hsp (1.5 ms) , 5 ms, 10 ms, 100 ms, 500 ms, 1 s, 5 s |
|||
高、走,低输出 |
NPN open collector, 50 mA max. (40 V or less), residual voltage: 1 V or less, N.O./N.C. switchable |
|||
Major functions |
Preset, Hold, Variable hysteresis, Variable response time, Multiplier setting, Bank function (4 banks), |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less*2 |
||
Environmental resistance |
Ambient temperature |
-10 to +55 °C14 to 131 °F(No freezing) |
||
相对湿度 |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: Polycarbonate, Cable: PVC |
|||
Accessories |
Panel mounting bracket, protective front cover, power cable, flat cable for expansion, instruction manual |
|||
Weight |
Approx. 110 g (: including panel mounting bracket, protective front cover, power cable) |
|||
*1One main unit and nine expansion units (ten in total) can be additionally installed. For additional amplifier unit installation, each output current must be 20 mA or less. |
||||

