Multi-Purpose CCD Laser Micrometer

IG series

CatalogsView Catalog

Sensor HeadIG-010

Specifications

Model

IG-010

Operation principle

CCD method

Light source

Wavelength

660 nm (Visible light semiconductor laser)

FDA

Class 1*1

IEC/JIS

Class 1

Mounting distance

0 to 1000 mm39.37"

Measurement range

10 mm0.39"

Sampling cycle

980 µs (When the number of times for averaging is set to [hsp]: 490 µs)

Minimum detectable object

High sensitivity mode

ø0.1 mmø0.003"(Setting distance: 100 mm3.94")*2

Standard mode

ø0.2 mmø0.007"(Setting distance: 40 mm1.57"or less),
ø0.5 mmø0.02"(Setting distance: 500 mm19.68")*2

Repeatability

5 µm0.20 Mil(Setting distance: 100 mm3.94")
10 µm0.39 Mil(Setting distance: 500 mm19.68")
80 µm3.15 Mil(Setting distance: 1,000 mm39.37")*3

Linearity

±0.28 % of F.S. (±28 µm±1.10 Mil)*4

Temperature characteristics

±0.03 % of F.S./°C (±3 µm±0.12 Mil/°C)*5

Operation indicator

Transmitter

Optical axis alignment indicator: Green LED, Power indicator: Green LED

Receiver

Optical axis alignment indicator: Green LED, Position monitor: Dual bar LED (Red, Green)

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp: 5,000 lux, Sunlight: 5,000 lux*6

Ambient temperature

-10 to +45 °C14 to 113 °F(No freezing)

相对湿度

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm0.06", 2 hours in each of the X, Y, and Z axis

Material

Case

Zinc die-cast (Lower case), PBT (Upper case), Polyarylate (PAR) (Display part), SUS304 (Metallic part)

Lens cover

Glass

Cable

PVC

Accessories

Transmitter × 1, Receiver × 1, Sensor head cables (2 m6.56') × 2

Weight

Approx. 380 g (including supplied items)

*1The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
*2When the measurement target object is measured at the center position of the setting distance. When the measurement mode is set to the glass edge mode, a glass edge of C0.1 mm0.003"or more can be detected (Setting distance: 500 mm19.69").
*3When the light is shielded by half at the center position of the setting distance. Vibration width when the average number of times is set to 16 and sampling is performed for 30 seconds. (When the analog output is used, the margin of error of analog output is added.)
*4When the setting distance is 100 mm3.94"and light is shielded at 50 mm1.96"position from the receiver. Margin of error to the ideal line.
*5When the setting distance is 100 mm3.94"and light is shielded by half at 50 mm1.96"position from the receiver.
*6Excluding when the average number of times is set to [hsp].