High-Performance Micro Static Eliminators
SJ-M series
Spot Type Amplifier UnitSJ-M200
Specifications
Model |
SJ-M200 |
|||
Type |
Controller |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec. max.*1 |
|||
Ion balance |
±15 V*2 |
|||
Supply pressure range |
0.001 to 0.5 MPa*3 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output |
||||
Condition alarm output |
||||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C32 to +104°F |
||
相对湿度 |
35 to 65%RH (no condensation)*3 |
|||
Weight |
Approx. 300 g |
|||
*1Operating distance: 50 mm1.97"风量:60问/min, |
||||